Handbook Errata
REVISED EDITION
FIRST EDITION
Page 57, Figure 2.7.5-2:
MIN label on right side of figure should be MAX.

Page 94, Table 6.1.1-1:
IrRAMP equation should be as follows:
IrRAMP = SQR(D/3*(Ipk^2+Ipk*Iped+Iped^2))

Page 100, Table 6.1.1-3:
The first term in PFiCM equation should be as follows:
D/3*(Ipk^2+Ipk*Iped+Iped^2)*rDS

Page 117, Equation 6.2-5:
Irect should be 0.707*Io/SQR(2*t*f)
Text should read, "...hence the rms amps are SQR(1/2) that of the transformer."
EXAMPLE: Irect = 0.707*Ixfmr = 3.30 amps rms

Page 129, Figure 6.4.1.1-2:
mSU label on right side of figure should be mHD.

Page 181, Example:
Vpu equation should be as follows:
Vpu = Ef*1.414*L*SIN(2.22*H/y)
i.e., insert "/y" just before the closing parenthesis.
Page 94, Table 6.1.1-1:
IrRAMP equation should be as follows:
IrRAMP = SQR(D/3*(Ipk^2+Ipk*Iped+Iped^2))

Page 100, Table 6.1.1-3:
The first term in PFiCM equation should be as follows:
D/3*(Ipk^2+Ipk*Iped+Iped^2)*rDS

Page 117, Equation 6.2-5:
Irect should be 0.707*Io/SQR(2*t*f)
Text should read, "...hence the rms amps are SQR(1/2) that of the transformer."
EXAMPLE: Irect = 0.707*Ixfmr = 3.30 amps rms